Safety, Reliability and Versatility
TEMEC CMXT Autonomous Gate
Hydraulic energy guarantee for bypass control, even in highly variable canal conditions. Fully autonomous, robust and reliable solution.
It allows modifying the regulated levels by manual or automated set point changes.
► Features
The solutions with this gates are designed to guarantee a high enough water level to pump without any problems, even with highly variable conditions in the canal. Also, if it is necessary to avoid keeping the upstream canal permanently full or to guarantee the downstream supply, MXT gates are used, which, in addition to fulfilling the AR1 gate function, perform other tasks.
This equipment allows the upstream level to be controlled to obtain: a minimum upstream level, a specific downstream level and a maximum downstream level, all at the same time and with the ability to be easily adjusted within a certain range.
This makes it possible to maintain a minimum level for pump operation, establish a level in the downstream pipeline that translates into a specific flow rate if the flow curve of the section is available, and accumulate water available in the upstream canal for use in the event of a change in the inflow. When the established upstream level is exceeded, the gate opens to prevent upstream overflows. The absence of motors and sensors contributes to the robustness and reliability of this equipment.
► Tips about use
This solution includes equipment inspired by a simple hydraulic design, totally autonomous, robust and devoid of any mechanical complication, allowing it to adapt to the most severe working conditions.
Features
- Guarantee of control of upstream levels.
- Guarantee of maximum downstream levels.
- Guaranteed functionality in severe weather conditions and safety in case of blockages.
- No electrical power is required for operation.
- High sensitivity to changes in canal.
- Allows set point changes to adapt to operational changes (remote controllable).
- Low and simple maintenance.
Tips about use
- It can be motorized and remote-controlled, with small DC motors and solar panel, simplifying the set point changeover operation.
- It requires knowing the flow curve of the downstream section to obtain the flow rate.
- Requires some rubber sealing equipment to achieve complete leak-tightness.
► Engineering and Selection
For dimensioning and selection of the appropriate model to include in the solution, as well as for installation instructions and other technical information, we invite you to see our technical brochure and t ponerse en contact our specialist.

Safety and Reliability
TEMEC CAR1 Autonomous Gate
Guarantee of constant upstream regulation, prioritizing the demand upstream of the installation. Completely autonomous, robust and reliable solution.
This solution does not allow the regulated levels to be modified once they have been defined on site.
► Features
These solutions guarantee a constant upstream level of these gates, controlled by floats and ballast weights. AR1 gates play a key role in the management of a canal, maintaining the maximum level by automatically opening and closing in accordance with the flow to be evacuated.
Prioritizes the pumping station over consumption in the downstream canal. The response to pump failure and the consequent back-pressure wave to the canal is immediate and autonomous. The absence of motors and sensors contributes to the robustness and reliability of this equipment.
► Tips about use
This solution includes equipment inspired by a simple hydraulic design, totally autonomous, robust and devoid of any mechanical complication, allowing it to adapt to the most severe working conditions.
Features
- Guarantee of constant upstream level.
- Low associated head loss.
- Guaranteed functionality in severe weather conditions.
- Guarantee and high precision of the regulated level.
- High reaction speed.
- Control of transitory flows in the event of rapid closure.
- No solids retained at the bottom of the canal.
- Low and simple maintenance.
Tips about use
- It does not open until it ensures the operating level.
- To know the through flow, it must be installed in association with another device or hydraulic solution that allows the measurement.
- Requires some rubber sealing equipment to achieve complete leak-tightness.
► Engineering and Selection
For dimensioning and selection of the appropriate model to include in the solution, as well as for installation instructions and other technical information, we invite you to see our technical brochure and t ponerse en contact our specialist.

Adaptable to existing projects
TEMEC Automated Slide Gates
For canals with expected flow, to give guarantee to the pumping station. Manual or automated solution.
This solution allows connection of the equipment to new or existing remote control systems.
► Features
These solutions propose the generation of a backwater upstream of the installation, to ensure control of the bypass using slide or radial gates.
The generation of an upstream backwater compatible with the minimum required level is done by installing a flat or sector gate that blocks the conduction. Allowing the discharge from the bottom, facilitates the removal of sediments and other accumulated material. It is essential to operate these gates constantly by skilled staff, ensuring that the opening is compatible with both the circulating flow and the required level upstream.
They are manufactured on demand, therefore they can be perfectly adapted to the existing civil works forms. These devices open or close in an automated way following commands that have been loaded into the remote control system. They also allow local manual operation.
► Tips about use
This solution includes equipment inspired by a simple hydraulic design, robust and free of any mechanical complication, allowing it to adapt to the most severe working conditions.
Features
- Adaptability to existing works.
- High sealing properties.
- Automated and manual operation allowed.
- Guaranteed functionality in severe weather conditions.
- No solids retained at the bottom of the canal.
- Simple maintenance.
Tips about use
- Requires software to calibrate upstream and downstream levels for the flow curve.
- Requires electrical power to operate in automated mode.
- Maintenance should be performed by personnel trained in electronics.
► Engineering and Selection
For dimensioning and selection of the appropriate model to include in the solution, as well as for installation instructions and other technical information, we invite you to see our technical brochure and t ponerse en contact our specialist.

Adaptable y versátil
Automatizada con Clapetas Abatibles
Para canalizaciones con caudal previsible, para dar garantía de dominio en la derivación. Solución manual o automatizable.
This solution allows connection of the equipment to new or existing remote control systems.
► Funcionalidad
Estas soluciones plantean la generación de un nivel mínimo deseado aguas arriba de la instalación, para garantizar dominio en la derivación, mediante el uso de clapetas abatibles de vertido superior.
En situaciones donde el hidrograma de funcionamiento del canal es conocido y predecible, se pueden instalar elementos diseñados para conservar un nivel mínimo determinado sin afectar significativamente la conducción cuando el caudal aumenta. Una solución simple y versátil es la utilización de clapetas con eje de giro en el fondo de la conducción.
Dependiendo de la operación, la clapeta genera una obstrucción parcial del flujo, creando un remanso correspondiente. De esta manera se garantiza el nivel de dominio deseado. Es importante destacar que este elemento requiere operación manual y debe ser abatido en momentos de aumento de caudal. Puede plantearse accionamiento automático mediante mecanismos reductores e incluso mediante una instalación oleo hidráulica.
► Características y consejos de utilización
This solution includes equipment inspired by a simple hydraulic design, robust and free of any mechanical complication, allowing it to adapt to the most severe working conditions.
Features
- Adaptabilidad a obras nuevas o existentes.
- Guaranteed functionality in severe weather conditions.
- Recomendadas para conducciones anchas y de poco calado.
- Simple maintenance.
Tips about use
- Puede generar retención de sólidos aguas arriba de la instalación por lo que debe preverse modo de limpieza hidráulica de la cámara.
- Requires electrical power to operate in automated mode.
- El mantenimiento debe ser realizado por personal capacitado en electrónica (para caso automatizado).
► Dimensionamiento y Selección
For dimensioning and selection of the appropriate model to include in the solution, as well as for installation instructions and other technical information, we invite you to see our technical brochure and t ponerse en contact our specialist.