Safety, Reliability and Versatility
TEMEC CMXT Autonomous Gate
Guarantee of constant regulation even in adverse weather conditions. Completely autonomous, robust and reliable solution.
It is possible to modify the regulated levels by manual or automated setpoint changes.
► Features
These solutions include civil works for small or medium-sized river intake, which include one or more gates controlled by floats and ballast weights, designed to maintain a specific downstream level defined by the user, according to the required flow rate. These devices open or close autonomously according to variations in the level of water in the channel, ensuring the downstream level constancy. The absence of motors and sensors contributes to the robustness and reliability of this equipment.
They enable set point changes to be made on the regulated levels if the customer requires it, either manually or with the automation of small devices inside the gate. This automation is focused on the management of the set point change, not on the adjustment operations of the gate itself in case of fluctuations in the water flow, a situation that will always continue autonomously by the gate's floats. This ensures efficient, trouble-free and reliable operation in severe and variable weather conditions.
►Tips about use
This solution includes equipment inspired by a simple hydraulic design, totally autonomous, robust and free of any mechanical complication, allowing it to adapt to the most severe working conditions.
Features
- Guarantee of constant and safe inflow to the intake, independent of fluctuations in the river.
- Guaranteed functionality in severe weather conditions and safety in case of blockages.
- No electrical power is required for operation.
- No solids are retained at the bottom of the canal.
- Allows set point changes to adapt to operational changes (remote controllable).
- Low and simple maintenance.
Tips about use
- It can be motorized and remote-controlled, with small DC motors and solar panel, simplifying the set point changeover operation.
- It requires knowing the flow curve of the downstream section to obtain the flow rate.
- Requires some rubber sealing equipment to achieve complete leak-tightness.
► Engineering and Selection
For dimensioning and selection of the appropriate model to include in the solution, as well as for installation instructions and other technical information, we invite you to see our technical brochure and to contact our specialists.

Safety and Reliability
TEMEC CAB1 Autonomous Gate
Guarantee of constant downstream regulation, restricting inflow to demand. Completely autonomous, robust and reliable solution.
This solution does not allow modification of the regulated levels once they have been set at the construction site.
► Features
These solutions include small to medium-sized civil river intake works that include one or more gates controlled by floats and ballast weights, designed to maintain a specific level downstream and in a precise way. These devices open or close autonomously according to variations in downstream demand, independent of the upstream level of the river. The absence of motors and sensors contributes to the robustness and reliability of this equipment.
►Tips about use
This solution includes equipment inspired by a simple hydraulic design, totally autonomous, robust and free of any mechanical complication, allowing it to adapt to the most severe working conditions.
Features
- Guarantee of constant and safe inflow to the intake, independent of fluctuations in the river.
- Low loss-of-head associated.
- Guaranteed functionality in severe weather conditions
- Guarantee and high regulated level precision.
- No electrical power is required for operation.
- No solids are retained at the bottom of the canal.
- Low and simple maintenance.
Tips about use
- No level regulated changes are allowed.
- To determine the through-flow, it must be installed together with another device or hydraulic solution that allows the measurement to be made.
- Requires some rubber sealing equipment to achieve complete leak-tightness.
► Engineering and Selection
For dimensioning and selection of the appropriate model to include in the solution, as well as for installation instructions and other technical information, we invite you to see our technical brochure and to contact our specialists.

Adaptable to existing projects
Automated with Slide Gates
For new or existing intakes, to guarantee water regulation and management.
This solution allows the equipment to be connected to new or existing remote control systems.
► Features
These solutions involve small, medium or large-scale civil river intake works that include one or more slide gates controlled by electric motors controlled by a sensor system upstream and downstream of the equipment, so as to dispense with manual operation.
For existing intake works, equipment is manufactured on request to perfectly adapt to the shape of the civil works. These devices open or close in an automated way following commands that have been loaded into the remote control system. They also allow local manual operation.
►Tips about use
This solution includes equipment inspired by a simple hydraulic design, totally robust and free of any mechanical complication, allowing it to adapt to the most severe working conditions.
Features
- Adaptability to existing works.
- High sealing properties.
- Automated and manual operation allowed
- Guaranteed functionality in severe weather conditions
- No solids are retained at the bottom of the canal.
- Simple maintenance.
Tips about use
- Requires software to calibrate upstream and downstream levels for the flow curve.
- Requires electrical power to operate in automated mode.
- Maintenance should be performed by personnel trained in electronics.
► Engineering and Selection
For dimensioning and selection of the appropriate model to include in the solution, as well as for installation instructions and other technical information, we invite you to see our technical brochure and to contact our specialists.